@@ -712,9 +712,14 @@ class LoggedIO:
|
|
|
key = None
|
|
|
else:
|
|
|
raise TypeError("_read called with unsupported format")
|
|
|
- if size > MAX_OBJECT_SIZE or size < fmt.size:
|
|
|
- raise IntegrityError('Invalid segment entry size [segment {}, offset {}]'.format(
|
|
|
- segment, offset))
|
|
|
+ if size > MAX_OBJECT_SIZE:
|
|
|
+ # if you get this on an archive made with borg < 1.0.7 and millions of files and
|
|
|
+ # you need to restore it, you can disable this check by using "if False:" above.
|
|
|
+ raise IntegrityError('Invalid segment entry size {} - too big [segment {}, offset {}]'.format(
|
|
|
+ size, segment, offset))
|
|
|
+ if size < fmt.size:
|
|
|
+ raise IntegrityError('Invalid segment entry size {} - too small [segment {}, offset {}]'.format(
|
|
|
+ size, segment, offset))
|
|
|
length = size - fmt.size
|
|
|
data = fd.read(length)
|
|
|
if len(data) != length:
|